What the cold actually does to a heat pump here
Winter nights in Miller County average 26°F, and that is the number that matters, because a standard heat pump starts falling short of its rated heat below 40°F and often leans on backup heat below about 35°F. Both marks sit above our average low. On about 100 nights a year, every night at or below freezing, a standard heat pump is working below both of those marks, not just some nights but about half the nights of the whole heating season.
That does not mean the heat pump quits. It means it is making less heat than its rating on a very ordinary night here, and the backup heat, usually electric resistance strips, is what fills the rest. That backup heat is what the $1.72 running-cost figure leaves out. It is built from the heat pump's seasonal rating alone, with nothing added for the nights it needs help.
The cold only gets severe a couple of nights a year. Zero degrees and below shows up about 2 nights out of the 100 that hit freezing, a small slice of the season. Field tests of cold-climate heat pumps found backup heat carrying only a small share of the load between 0°F and 35°F, and running on backup alone was rare even at 0°F. That is the newer, cold-climate class of equipment, built to hold 70 percent of its capacity at 5°F. A standard heat pump, the one priced in the running-cost band above, does not carry that rating.