Most homes here run on electric heat
Electricity heats 68.4% of the homes in Miller County. A heat pump fits right into that, since it runs on the same power your home already has.
Takes about a minute. No obligation.
Electricity heats 68.4% of the homes in Miller County. A heat pump fits right into that, since it runs on the same power your home already has.
No gas line to deal with, no venting to redo. Wiring and setup can follow what's already there, which keeps the job more straightforward.

NOAA nClimDiv, 1991–2020 normals
The rating on the label is an average over a full season, not a single cold or hot day.
A heat pump can carry a high rating and still work harder once temperatures drop toward freezing, so ask what it's rated to put out at that point.




Eldon sits in climate zone 4A, a mixed climate that asks real work of both sides of a heat pump, the heating and the cooling. Any split-system heat pump installed here has to meet federal minimums for units made since January 2023. That floor is 14.3 SEER2 for cooling and 7.5 HSPF2 for heating, and it limits what a contractor can legally put in your house. A federal tax credit is available for heat pumps that qualify, separate from whatever the unit costs to run month to month. Ask what rating a given system carries before you weigh it against another.
A standard size and efficiency fit fine here. There's no local reason to go bigger or pricier.
Find a contractorA heat pump that's too big will still cool the house, but it does it in short bursts. It cools the air fast, shuts off before it pulls the moisture out, and starts up again a few minutes later. Rooms feel clammy even though the thermostat says the temperature is fine. One that's too small just runs and runs, straining to catch up on the coldest or hottest days and wearing down its compressor sooner for the effort. Getting the size right isn't a guess. A contractor measures the house itself, the square footage, how many windows it has and which way they face, how much insulation is in the attic and walls, even the layout of the ductwork, and runs that through a load calculation. The number that comes out tells them the capacity the house actually needs, not the one that looks impressive on paper. Every hour the system runs, it's working against whatever size was chosen at the start.
Every heat pump reaches a temperature where it can no longer pull enough heat from outside air to keep up, and a backup heat source has to take over. Ask where that point is for a given system and what kicks in when it's reached. A unit with a lower balance point carries more of the heating load on its own before backup heat has to help.
A heat pump moves a different volume of air than whatever it's replacing, and ducts sized for one system don't always suit another. Ask whether the existing ductwork was checked, not just the outdoor unit swapped in. Leaks, crushed runs, or ducts that are too small will cut into what the new system can deliver no matter how it's rated.
Taking out the old system is its own job, separate from putting in the new one. If it's a straight swap, the old unit gets disconnected, the refrigerant lines drained or replaced, and the outdoor unit hauled off. Refrigerant can't just be vented into the air, so a licensed contractor has to recover it properly before anything comes apart. If the old system ran on gas or had a furnace paired with it, that gets capped or removed too, depending on whether the heat pump is taking over the job alone or working alongside it. None of this is something to do yourself, and most of it happens in a day, before the new equipment goes in.
On install day the outdoor unit and the indoor coil both get set in place, and the crew moves between them as the work goes. Electrical connections get made to match the new equipment. Refrigerant lines get connected and tested for leaks before anything is charged, since a leak found after the fact means pulling the system apart again. Once the lines hold pressure, the system gets charged to the amount the manufacturer specifies for that unit, not whatever the old system used to run on. The thermostat gets wired in and set to talk to the new equipment, which can take some extra work if the old system used a different kind of control. Before the crew leaves, the system gets run through both heating and cooling, so any problem shows up that day instead of the first cold morning after.