What winter here actually asks of a heat pump
Your heat runs seven months a year here, October through April, so whichever machine you pick spends most of its life heating, not cooling. That alone makes the heating argument the one that matters most.
A standard heat pump starts falling short of its rated output below 40°F, and often needs backup heat once it drops below about 35°F. The overnight low here averages 29°F across December, January and February. That is below both marks, and every one of the roughly 85 nights a year that hit freezing or below is below both marks too. So on a normal winter night, a standard heat pump in Stoddard County is working below the point where it heats at full strength.
That does not mean it is struggling all winter. Only about one night a year here reaches 0°F, the temperature where backup heat really gets tested. Field testing on cold-climate heat pumps found that backup heat carried only a small share of the load between 0°F and 35°F, and that running on backup alone was rare even down to 0°F. The hard nights are real, but they are few.
If you want a heat pump that is built for this, look for the ENERGY STAR Cold Climate rating. To earn it, a heat pump has to produce at least 1.75 units of heat per unit of electricity at 5°F and hold on to 70 percent of its 47°F capacity at that same temperature, checked by independent testing. A standard heat pump is not tested to that mark. For a county where the winter low averages 29°F and sits at or below freezing on about 85 nights, that difference is worth paying attention to.