What the cold here does to a heat pump
Winter here is the long season, not the short one. Heat runs seven months, October through April, against four months of cooling. Whatever you install spends most of its working life heating this house, so heating performance is where this decision gets made.
The overnight low averages 27°F across December, January and February. That number matters because a standard heat pump has two different breakpoints, and 27°F is past both of them. Below 40°F its heat output starts falling short of its rating. Below about 35°F it often needs backup heat to make up the difference. An average winter night here is below both marks already, and that is before the cold snaps.
About 105 nights a year, roughly half the nights across the heating season, fall at or below freezing. On those nights a standard heat pump is working below its rated capacity and likely leaning on backup heat to keep the house warm. That is not an occasional cold snap. That is close to half the winter.
The one piece of good news is how rarely it gets truly cold. Nights at 0°F or below happen about once a year here. A two winter field test of cold climate heat pumps in occupied homes found backup heat covered only a small share of the output between 0°F and 35°F, and running on backup alone was rare even above 0°F. That test used cold climate equipment, built to hold at least 70 percent of its capacity at 5°F and still turn 1.75 units of heat per unit of electricity there, verified by outside testing. A heat pump bought to that standard handles this county's nights much better than a standard model does. A heat pump bought to the federal minimum does not carry that same guarantee.