Electricity already runs most homes here
Electricity heats 53.5% of homes in Callaway County, more than any other fuel. Gas, utility and bottled together, heats roughly the rest. A heat pump fits in with what's already common in Fulton.
Takes about a minute. No obligation.
Electricity heats 53.5% of homes in Callaway County, more than any other fuel. Gas, utility and bottled together, heats roughly the rest. A heat pump fits in with what's already common in Fulton.
If your home already heats with electricity, a heat pump goes in without adding gas lines or new fuel service. The wiring and panel are already set up for an electric system, which is the main thing a contractor checks before installing one.

NOAA nClimDiv, 1991–2020 normals
A standard heat pump, sized right for the house, is what most homes here need.
Missouri electricity runs 12.91 cents per kilowatt-hour, so there's no local reason to pay more for capacity you won't use.



September is the month to get this done. Heat here starts in October, and a heat pump that goes in before that gives everyone time to work through any setup issues before you're depending on it to keep the house warm. Wait until the first cold snap and you're scheduling around whatever openings are left, not what works for you. The same system is about to switch over and run cooling again in May, so it's worth getting the install right the first time rather than rushing it in October.
Callaway County falls in a mixed climate zone, 4A, where summers run humid and winters still ask a lot of a heating system. Any heat pump installed here has to clear federal minimums of 14.3 SEER2 for cooling and 7.5 HSPF2 for heating. That sets the floor for what can go into your home, and a system meeting it also qualifies for the federal tax credit available on qualifying heat pumps.
Find a contractorA heat pump that's too big satisfies the thermostat fast and shuts off again before it's pulled the moisture out of the air or warmed the house evenly. It cycles on and off all day instead of settling into a steady run. One that's too small never gets ahead. On the coldest and hottest days it runs constantly and still can't quite hold the temperature you set. Either way the wear lands on the compressor and the reversing valve, the parts that let the system switch between heating and cooling. Sizing isn't a guess based on square footage. A contractor works out a load calculation that accounts for wall and window area, which way the windows face, how much insulation is in the attic and walls, and how much air leaks in and out. Houses that look about the same from outside can still need different sized systems once that's worked through. Done right, the heat pump runs long and steady, and that steady run is also what lets it pull moisture out of the air properly in summer.
Every heat pump loses capacity as the temperature outside drops, and each one has a point where it can't pull enough heat from the outside air to keep up on its own. Ask where that point is for the system you're comparing, and what covers the gap. Some rely on electric resistance strips kicking in, others use a cold-climate compressor designed to keep working much further down. The answer tells you how the house actually feels on the hardest night of the year, not just what the rating sheet says.
A heat pump needs a technician who can get parts for it and knows its controls, not just on install day but years out when the compressor or the reversing valve needs attention. Ask the contractor whether they install and service this equipment regularly or whether it's something they can order but rarely work on. A system backed by a contractor who already knows it gets fixed faster when something goes wrong than one that's unfamiliar to everyone you'd call.
The SEER2 and HSPF2 numbers on the label are a ceiling measured in a lab, not a promise of what you'll see on your power bill. They tell you how efficiently the system can move heat under ideal conditions, with clean coils, correct charge and steady airflow. A higher rating usually means a more efficient compressor and often a variable-speed one, which can run at partial capacity instead of snapping between full blast and off. That matters more than the number itself, because a system that modulates holds a steadier temperature and runs quieter than one that only knows on and off. The rating also assumes the ductwork and sizing are right. A high-efficiency unit choked by undersized ducts or paired with the wrong size for the house won't deliver what the label suggests.
Install day starts with the old equipment coming out, not the new one going in. A tech disconnects the refrigerant lines, pulls the old line set if it isn't being reused, and takes the indoor and outdoor units off their mounts. The outdoor unit goes on a new pad, leveled, with clearance on all sides so air can move through the coil. Indoors, the air handler or coil ties into the ductwork, and that connection is where a lot of the real work happens. Joints get sealed so the system pulls air from the room it's supposed to heat, not from a crawlspace or attic. Once the line set is run and connected, the system gets evacuated to pull moisture and air out of the lines before refrigerant goes in. It's charged to the weight the manufacturer specifies, not just until the gauges look about right. Last comes startup, checking airflow, checking that the system switches cleanly between heating and cooling, and confirming the thermostat is talking to the equipment the way it should.