What winter here does to a heat pump
Your furnace or heat pump runs seven months a year here, October through April, and the overnight low averages 23°F across the worst of it. That number matters because 23°F is already past the point where a standard heat pump starts losing ground. Below 40°F a conventional heat pump puts out less than its rated capacity, and below about 35°F it often needs backup heat to make up the difference. The average winter night here is below both marks, and so is every one of the roughly 105 nights a year that drop to freezing or below.
That doesn't mean a heat pump can't heat your house. It means it needs help doing it on more than half the nights of the heating season. The backup is usually electric resistance heat, and it's the one thing missing from the $1.72 figure in the cost comparison above. That number is the heat pump running at its rated efficiency, with nothing added for the nights it leans on backup. Your actual cost falls somewhere above it, and how far above depends on how often your backup kicks in.
It's worth knowing the cold doesn't go as deep as it sounds. Only about 3 nights a year here reach 0°F, and that's the range where a standard heat pump struggles most and backup heat does the most work. A cold-climate heat pump, the kind certified to hold 70 percent of its capacity and still produce 1.75 units of heat per unit of electricity at 5°F, is built for exactly those nights. Field tests of that equipment found backup heat carried only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. The gap between a standard heat pump and a cold-climate one matters most in a county where the average night is 23°F.