Winter here is the long season, seven months of heat against five months of cooling. The overnight low averages 22°F across December, January and February, and that number is the one that matters for this decision. A standard heat pump starts losing ground below 40°F and often needs backup heat below about 35°F. Here, the average winter night is already past both marks.
About 110 nights a year drop to freezing or below, roughly half the nights across the heating season. On those nights a standard heat pump is not putting out its full rated capacity, and on a good share of them it is leaning on backup heat to make up the difference. That is not a rare cold snap. That is most of the winter.
The nights that reach 0°F are few, about 4 a year. A field test of cold-climate heat pumps in real homes found backup heat carried only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. The gap is that standard models are not built to the same standard. If a heat pump goes into this house, the one that holds up on a 22°F night and still has something left at 5°F is the ENERGY STAR Cold Climate kind, rated to make at least 1.75 units of heat per unit of electricity at 5°F and keep 70 percent of its warm-weather capacity there. A standard heat pump was not tested to do that, and this county asks for it more nights than not.