Running right
The outdoor unit sits on its pad, fan turning, coil clean and clear of ice. Refrigerant lines run to the disconnect box without any sign of trouble. This is a heat pump pulling heat from the outside air, not leaning on backup.
Get matched with a pro who works on heat pumps in Cass County.
Connect with a proA heat pump stuck on emergency heat usually means the outdoor unit has stopped running and the system has switched over to its backup electric strips or your gas furnace to keep the house warm. Most often the cause is a frozen or iced-over outdoor coil, a tripped breaker, or a thermostat setting left on "emergency heat" by mistake after a cold snap. With Cass County winters, ice on that outdoor unit is the most common reason the system gives up on the heat pump and falls back to backup heat. It can also mean the compressor or a sensor has actually failed, which is why it won't switch back on its own. Either way, running on emergency heat for more than a day or two costs you, since it relies on backup heat instead of the heat pump itself. It is worth having someone check why the switch happened rather than just resetting the thermostat.
Winter nights average 24°F
Nights here average 24°F in December, January and February, cold enough to push a struggling heat pump into backup mode often.
Heat runs October through April
Heat runs October through April here, about seven months. That is a long stretch for a stuck heat pump to run up your bill.
Cooling runs May through September
Cooling runs May through September. The outdoor unit works hard all year, so a fix now matters before summer asks more of it.
NOAA nClimDiv 1991-2020
Emergency heat is a deliberate state, not a malfunction by itself. Somewhere in the system, a switch or a control board decided the outdoor unit should not run right now, and it handed the job to backup heat strips or a furnace instead. On most thermostats this shows up as an "EM HEAT" light, and it will stay lit until either the thermostat is switched back or whatever caused the lockout gets fixed. The distinction that matters is between emergency heat and auxiliary heat. Auxiliary heat kicks in alongside a compressor that's still working, usually on the coldest mornings when the heat pump alone can't keep up. Emergency heat means the compressor is shut out entirely. A contractor troubleshooting this starts at the outdoor unit. If the reversing valve is stuck, the system can't switch back into heating mode even after a defrost cycle finishes, so it defaults to backup. If refrigerant has leaked out, the outdoor coil can't pull enough heat from the air, and the control board will eventually give up on it. A tripped breaker or a safety switch on the unit itself, often from a motor drawing too much current, will keep it dark until someone resets it and finds out why it tripped. And sometimes the cause is simpler: a manual emergency heat setting left on by accident after the power blinked or after a cleaning, with nothing wrong outside at all.


Your house will likely stay warm. That's what emergency heat is for. The strips or the furnace backing it up are built to carry the load, even on a night near zero. What changes is what it costs you and what it hides. Electric strips pull a lot of power compared to the outdoor unit doing the same job, and if the thermostat stays stuck on that setting, the bill reflects every hour of it. A gas furnace stepping in costs less to run, but either way the heat pump itself isn't working. It's sitting there while something else carries the house. If ice caused the switch in the first place, that ice isn't melting while the outdoor unit stays off, so whatever started this can still be sitting on the coil when the system tries to switch back. You might notice the air itself feels a little different, less even, since backup heat doesn't move warmth through the house quite the way the heat pump does. None of this damages anything by running. It just means the system needs a look before the next cold stretch comes through Cass County.




A heat pump that won't come off emergency heat isn't going to fix itself by waiting it out. The switch that put it there, whether it's a bad thermostat signal, a sensor on the outdoor unit, or a breaker that tripped, needs someone to look at the equipment directly. Meanwhile your gas furnace or electric strips keep the house warm, so there's no rush born of the cold itself. The rush is the bill. Backup heat is built to cover you through a cold snap, not to run for days on end, and a Raymore winter gives it plenty of chances to keep running if nobody resets what's wrong. The outdoor unit sitting idle isn't resting, it's broken, and every night it stays off is another night the furnace or the strips do the work alone. Getting a contractor looking at it sooner means fewer of those nights stack up before the heat pump is back to doing its share.
Go look at the outdoor unit. If the coil is covered in ice or frost and the fan isn't turning, that's usually what pushed the system into emergency heat in the first place. A heat pump is supposed to collect heat from the outside air even when it's cold, and to do that it runs a defrost cycle on its own every so often to clear frost off the coil. If that cycle isn't kicking in, ice builds up until the system can't pull heat from the air at all, and the control board shuts the outdoor unit down and switches to backup. A coil that's iced solid in the afternoon, not just after a cold night, is a sign the defrost cycle itself has stopped working.
Check the breaker for the outdoor unit while you're at it. A tripped breaker will stop the outdoor unit cold, and the thermostat has no way to know why, it only knows the unit isn't responding, so it falls back to emergency heat to keep the house warm. If the breaker is tripped and resets cleanly and holds, that was likely the whole problem. If it trips again once the outdoor unit tries to start, something in the unit itself is drawing too much power, and that's a job for someone who can test the compressor and wiring directly rather than one more reset.
At 13.08 cents per kilowatt-hour, running electric strips to heat your Raymore house isn't cheap, but it isn't the kind of number that should scare you into ignoring the problem either. The real cost is leaving a heat pump stuck on backup heat for weeks because nobody looked at why the switch happened.
EIA-861 2025
Leave it on emergency heat until someone can look at it, and your house stays warm the whole time. The furnace or strips don't care why the outdoor unit stopped, they just keep running.
Leave it stuck there for weeks and you're paying for backup heat the whole time, plus whatever caused the switch in the first place is still broken and waiting to cause the next problem.



The outdoor unit sits on its pad, fan turning, coil clean and clear of ice. Refrigerant lines run to the disconnect box without any sign of trouble. This is a heat pump pulling heat from the outside air, not leaning on backup.

The outdoor unit sits quiet next to the house, fan still, no sound coming from it. The lines and disconnect look the same as always, but nothing inside the unit is moving. That silence is what sends a heat pump to emergency heat.

A heat pump stuck on emergency heat isn't an emergency for your house. The furnace or the strips keep the rooms at temperature while the outdoor unit sits idle. What it is, is a sign that something, a frozen coil, a bad sensor, a stuck relay, a tripped breaker, took the outdoor unit out of the loop and nothing has put it back. That doesn't resolve on its own. It waits for someone to look at the equipment.
You don't have to figure out which of those it is before you ask for help. That's the point of having someone come look. Once you send the request, finding the right person for your system stops being something you have to sort out. A contractor who works on heat pumps in Cass County gets the details of your situation and reaches out to you directly. You go back to the thermostat, not the troubleshooting.



Find a heat pump repair pro in Cass County
After you send the request, you're done searching.